Structure |
|
|
 |
|
 |
Features |
|
These wires consists of UEW (polyurethane
copper wires) extrusion-coated with fluorovinylidene. |
|
They have high mechanical strength including
cut-through resistance and wear resistance, making them ideal as lead wires. |
|
 |
Ratings |
|
105 ,300V |
|
 |
Applications |
|
For wrapping around electronic devices, and
also as noise prevention coils in TV receivers. |
|
 |
Specifications |
UL
style
No.
|
Conductor |
Insulation |
Max
conductor
resistance
(20 )
Ω/km
|
| AWG |
Cross-sectional
area
mm2
|
Composition
No./mm
|
O.D.
mm
|
Thickness
mm
|
Standard
O.D.
mm
|
| 1501 |
29 |
0.071 |
1/0.30 |
0.35 |
0.175 |
0.70 |
262.9 |
| 28 |
0.096 |
1/0.35 |
0.40 |
0.175 |
0.75 |
191.2 |
| 27 |
0.126 |
1/0.40 |
0.45 |
0.175 |
0.80 |
145.3 |
| 25 |
0.196 |
1/0.50 |
0.55 |
0.175 |
0.90 |
91.4 |
| 23 |
0.283 |
1/0.60 |
0.66 |
0.18 |
1.02 |
65.3 |
| 22 |
0.385 |
1/0.70 |
0.76 |
0.18 |
1.12 |
47.5 |
| 21 |
0.502 |
1/0.80 |
0.86 |
0.18 |
1.22 |
36.1 |
| 20 |
0.636 |
1/0.90 |
0.97 |
0.18 |
1.33 |
28.4 |
|
|
UL
style
No.
|
Rating |
Min
conductor
resistance
(20 )
MΩkm
|
Insulation
withstand
voltage
(AC)
V for 1 minute |
Standard
length
ft
(m)
|
Temperature

|
Voltage
V
|
| 1501 |
105 |
300 |
200 |
2000 |
1000
(305)
|
|
|
|