Structure
Features
Although these wires have a small finished diameter, they have excellent cut-through resistance and wear resistance, so they are ideal as lead wires.
Ratings
105
, No voltage specification
Applications
For wrapping around electronic devices, and also as lead wires for small coils, and so on
Specifications
UL
style
No.
Conductor
Insulation
Max
conductor
resistance
(20
)
Ω/km
AWG
Cross-sectional area
mm
2
Composition
No./mm
O.D.
mm
Thickness
mm
Standard
O.D.
mm
1426
(Stranded
wire)
32
0.035
7/0.08
0.24
0.17
0.58
586
30
0.055
7/0.10
0.30
0.17
0.64
373
28
0.089
7/0.127
0.38
0.17
0.72
238
26
0.141
7/0.16
0.48
0.17
0.82
148
24
0.220
7/0.20
0.60
0.17
0.94
93.3
22
0.355
7/0.254
0.76
0.17
1.10
59.2
20
0.563
7/0.32
0.96
0.17
1.30
37.2
1426
(Single
wire)
32
0.032
1/0.203
0.203
0.17
0.54
572
30
0.051
1/0.254
0.254
0.17
0.59
371
28
0.080
1/0.32
0.32
0.17
0.66
232
26
0.126
1/0.40
0.40
0.17
0.74
145
24
0.204
1/0.51
0.51
0.17
0.85
89.3
22
0.322
1/0.64
0.64
0.17
0.98
56.3
20
0.515
1/0.81
0.81
0.17
1.15
35.2
UL
style
No.
Rating
Min
conductor
resistance
(20
)
MΩkm
Insulation
withstand
voltage
(AC)
V for 1 minute
Standard
length
ft
(m)
Temperature
Voltage
V
1426
(Stranded
wire)
105
No provisions are decided.
200
1000
3000
(915)
2000
(610)
1426
(Single
wire)
3000
(915)
2000
(610)