>>TOTOKU TOP

>>HOME>>To the Japanese page

>>Company Profile>>PDF Catalogue>>Sitemap>>Contact Us

Magnet Wires Coil Electric Wires Optical Products Display Liquid Processing Filters

Fluororesin insulated wires
FZW ETFE wires for devices
Structure
Structure
Features
The maximum working temperature is 150.
The dielectric constant is only 2.6 (10 MHz), resulting in excellent high frequency characteristics. Also, the tensile strength of the insulation is twice that of FEP, ensuring excellent mechanical strength.
These wires have excellent resistance to oil, cold, and chemicals, and do not readily burn.
Applications
Wiring for electronic calculators and data devices, and also lead wires for small coils, relays, and so on
Specifications
Type Conductor Insulation max
conductor
resistance
(20)
Ω/km
Nominal
cross-
sectional
area
mm2
Composition
No./mm
O.D.
mm
Standard
thickness
mm
Standard
O.D.
mm
FZW-L - 1/0.32 0.32 0.15 0.62 243
1/0.40 0.40 0.15 0.70 154
1/0.50 0.50 0.15 0.80 95.2
1/0.65 0.65 0.15 0.95 57.7
1/0.80 0.80 0.2 1.20 37.6
0.08 7/0.12 0.36 0.15 0.66 239
0.14 7/0.16 0.48 0.15 0.78 134
0.18 7/0.18 0.54 0.2 0.94 106
0.21 19/0.12 0.60 0.2 1.00 88
0.30 12/0.18 0.74 0.2 1.14 61.9
0.37 7/0.26 0.78 0.2 1.18 50.3
FZW-M - 1/0.50 0.50 0.25 1.00 95.2
1/0.65 0.65 0.25 1.15 57.7
1/0.80 0.80 0.3 1.40 37.6
0.37 7/0.26 0.78 0.3 1.38 50.3
0.5 19/0.18 0.90 0.3 1.50 39.1
0.75 30/0.18 1.20 0.3 1.80 25.1
1.25 50/0.18 1.50 0.35 2.20 15.1
2.0 37/0.26 1.80 0.4 2.60 9.79

Type Min
conductor
resistance
(20)
MΩkm
Insulation
withstand
voltage
(AC)
V for 1 minute
Standard
length
ft
(m)
FZW-L 50000 1500 300 max
FZW-M 50000 3000 600 max

Electric Wire TOP INDEX