Structure |
 |
|
 |
Features |
| |
Although these wires have a small finished
diameter, they have excellent cut-through resistance and wear resistance, so they
are optimum as lead wires. |
|
They have excellent heat resistance. The
maximum working temperature is 150 . |
|
 |
Applications |
| |
Back panel wiring of electronic calculators,
wrapping wires for data and communication devices, and lead wires for small coils,
relays, and so on. |
|
 |
Specifications |
| Type |
Conductor |
Insulation |
Max
conductor
resistance
(20 )
Ω/km
|
Nominal
cross-
sectional
area
mm2
|
Composition
No./mm
|
O.D.
mm
|
Standard
thickness
mm
|
Standard
O.D.
mm
|
| FVW-L |
- |
1/0.32 |
0.32 |
0.15 |
0.62 |
243 |
| 1/0.40 |
0.40 |
0.15 |
0.70 |
154 |
| 1/0.50 |
0.50 |
0.15 |
0.80 |
95.2 |
| 1/0.65 |
0.65 |
0.15 |
0.95 |
57.7 |
| 1/0.80 |
0.80 |
0.15 |
1.10 |
37.6 |
| 0.08 |
7/0.12 |
0.36 |
0.15 |
0.66 |
239 |
| 0.14 |
7/0.16 |
0.48 |
0.15 |
0.78 |
134 |
| 0.18 |
7/0.18 |
0.54 |
0.16 |
0.86 |
106 |
| 0.21 |
19/0.12 |
0.60 |
0.16 |
0.92 |
88 |
| 0.30 |
12/0.18 |
0.74 |
0.16 |
1.06 |
61.9 |
| 0.37 |
7/0.26 |
0.78 |
0.16 |
1.10 |
50.3 |
| FVW-M |
- |
1/0.50 |
0.50 |
0.25 |
1.00 |
95.2 |
| 1/0.65 |
0.65 |
0.25 |
1.15 |
57.7 |
| 1/0.80 |
0.80 |
0.25 |
1.30 |
37.6 |
| 0.08 |
7/0.12 |
0.36 |
0.25 |
0.86 |
239 |
| 0.14 |
7/0.16 |
0.48 |
0.25 |
0.98 |
134 |
| 0.18 |
7/0.18 |
0.54 |
0.25 |
1.04 |
106 |
| 0.22 |
7/0.20 |
0.60 |
0.25 |
1.10 |
84 |
| 0.37 |
7/0.26 |
0.78 |
0.25 |
1.28 |
50.3 |
|
|
| Type |
Min
conductor
resistance
(20 )
MΩkm
|
Insulation
withstand
voltage
(AC)
V for 1 minute |
Standard
length
ft
(m)
|
| FVW-L |
30 |
1500 |
250 max |
| FVW-M |
40 |
3000 |
600 max |
|
|
|
|
|
|