Structure |
|
|
 |
|
 |
Features |
|
The maximum working temperature is 200 . |
|
These wires have excellent electrical characteristics
including small dielectric constant and dielectric loss. |
|
These wires have excellent resistance to
heat, cold, oil and chemicals, and do not burn. |
|
 |
Applications |
| |
Wiring of electronic devices and data devices. |
|
 |
Specifications |
| Type |
Conductor |
Insulation |
Max
conductor
resistance
(20 )
Ω/km
|
Nominal
cross-
sectional
area
mm2
|
Composition
No./mm
|
O.D.
mm
|
Standard
thickness
mm
|
Standard
O.D.
mm
|
| FEPW-L |
- |
1/0.32 |
0.32 |
0.15 |
0.62 |
243 |
| 1/0.40 |
0.40 |
0.15 |
0.70 |
154 |
| 1/0.50 |
0.50 |
0.15 |
0.80 |
95.2 |
| 1/0.65 |
0.65 |
0.15 |
0.95 |
57.7 |
| 1/0.80 |
0.80 |
0.20 |
1.20 |
37.6 |
| 0.08 |
7/0.12 |
0.36 |
0.15 |
0.66 |
239 |
| 0.14 |
7/0.16 |
0.48 |
0.15 |
0.78 |
134 |
| 0.18 |
7/0.18 |
0.54 |
0.20 |
0.94 |
106 |
| 0.21 |
19/0.12 |
0.60 |
0.20 |
1.00 |
88 |
| 0.30 |
12/0.18 |
0.74 |
0.20 |
1.14 |
61.9 |
| 0.37 |
7/0.26 |
0.78 |
0.20 |
1.18 |
50.3 |
| FEPW-M |
- |
1/0.50 |
0.50 |
0.25 |
1.00 |
95.2 |
| 1/0.65 |
0.65 |
0.25 |
1.15 |
57.7 |
| 1/0.80 |
0.80 |
0.3 |
1.40 |
37.6 |
| 0.37 |
7/0.26 |
0.78 |
0.3 |
1.38 |
50.3 |
| 0.5 |
19/0.18 |
0.90 |
0.3 |
1.50 |
39.1 |
| 0.75 |
30/0.18 |
1.20 |
0.3 |
1.80 |
25.1 |
| 1.25 |
50/0.18 |
1.50 |
0.35 |
2.20 |
15.1 |
| 2.0 |
37/0.26 |
1.80 |
0.4 |
2.60 |
9.79 |
|
|
| Type |
Min
conductor
resistance
(20 )
MΩkm
|
Insulation
withstand
voltage
(AC)
V for 1 minute |
Standard
length
ft
(m)
|
| FEPW-L |
50000 |
1500 |
max 300 |
| FEPW-M |
50000 |
3000 |
max 600 |
|
|
|